Grüntek Energy SolutionsGrüntekENERGY SOLUTIONS

SOLUTION · 03

Retrofit & installation
Replace what’s costing you. Keep what isn’t.

HVAC retrofit, refurbishment and installation in live, occupied buildings such as hotels and office towers, phased to keep disruption to a minimum and handed over as a commissioned, working system.

WHAT WE DELIVER

Retrofit & installation

HVAC retrofit, refurbishment and installation in live, occupied buildings such as hotels and office towers, phased to keep disruption to a minimum and handed over as a commissioned, working system.

PICVs and hydronic balancing

Replacing 3-way and 2-way valves with PICVs on FCUs and AHUs so every unit holds its required flow. See the PICV page for how it works.

Air-handling units

Replacement and refurbishment of AHUs, including modular units built in place where plant-room access is restricted.

Cooling coils and VAV boxes

Fouled or failed coils and VAV terminals replaced with correctly selected equipment and re-commissioned.

VFDs and motor control

Variable-frequency drives on fans and pumps so equipment follows the load instead of running at fixed speed.

Chilled-water pumps

Pump sets and drives supplied and installed, sized to the network’s actual hydraulic profile, including conversion from constant to variable flow.

Heat pumps and calorifiers

Calorifier replacement with water-source heat pumps for domestic hot water, plus heat-pump relocation and recommissioning.

Packaged units and air curtains

Supply and installation of packaged air-conditioning plant and air curtains in operational hotels and commercial buildings.

RETROFIT READINESS CHECK

Six questions.
Where to start.

Answer six quick questions about your building to see how much retrofit opportunity there is and which measures we would look at first.

  1. 01How old is the building’s HVAC system?
  2. 02What control valves are on the terminals (FCUs / AHUs)?
  3. 03How do the chilled-water pumps run?
  4. 04Where does the cooling come from?
  5. 05Do occupants complain about hot or cold areas?
  6. 06What building management system (BMS) is in place?

OCCUPIED BUILDINGS

Upgrade the plant.
Minimal disruption.

Hotels, offices and residential towers cannot simply switch off. We plan every retrofit around the people using the building.

Phased floor by floor

Work is split into zones so the rest of the building keeps its cooling while each section is done.

Pipe freezing

Where a section has to be isolated without draining the system, pipes can be frozen locally to form a temporary plug.

Hot tapping

New connections can be made on live pipework, avoiding a shutdown where the application allows it.

Agreed shutdown windows

When a short shutdown cannot be avoided, it is planned and agreed with facilities management in advance.

Out-of-hours work

Noisy or critical activities can be scheduled at night or at weekends to suit the building.

How we deliver a retrofitPhased to keep disruption to a minimum.
  1. AssessSurvey the existing plant
  2. SelectSize to today’s load
  3. InstallPhased, in a live building
  4. CommissionProve it under real load
  5. Hand overWith maintenance support

BEFORE AND AFTER

Cooling-coil replacement.
Jumeirah Emirates Towers.

Drag the handle to compare.

Replacement cooling coil installedOriginal cooling coil before replacement

RELATED WORK

Projects in this area.

All projects

PRODUCTS & PLATFORMS

What we use.

Representative air-handling unit.
Representative air-handling unit.

AHUs, cooling coils & VAVs

Upgrade air-handling and terminal equipment.

Product details
Representative HVAC pumping installation.
Representative HVAC pumping installation.

Chilled-water pumps & VFDs

Equipment for pumping and fan systems.

Product details
Representative water-to-water heat pump; branding removed for illustration.
Representative water-to-water heat pump; branding removed for illustration.

Heat pumps

Heat-pump supply, installation and relocation.

Product details
Rosenberg EC fan.
Rosenberg EC fan.
  • Rosenberg

Rosenberg EC fans

EC fans for ventilation and air-conditioning systems.

Product details
Representative air curtain; project configuration may differ.
Representative air curtain; project configuration may differ.
  • Rosenberg

Rosenberg air curtains

Turnkey air-curtain installation.

Product details

Keep it performing with an AMC.

Comprehensive and non-comprehensive AMCs for chillers, condensing units, HVAC, ETS, BMS and metering.

FAQ

Common questions.

Can you work in an occupied building?

Yes, with minimal disruption. Work is phased floor by floor or zone by zone. Where a section has to be isolated we use techniques such as pipe freezing and hot tapping, and any short shutdown that cannot be avoided is agreed with facilities management in advance.

Which brands do you install?

We are not tied to a single manufacturer. Equipment is selected for the application and the client’s specification, and handed over commissioned and documented.

Do we need to replace the whole system?

Not always. Refurbishing or replacing the components that dominate consumption, such as coils, fans and drives, can restore performance and extend equipment life.

Let’s talk about your building.

Contact our team